Question Engine
Describe the problem.
Get a technical answer.
Stop searching through forums and hundreds of pages of documentation. Just ask your question in natural language and get instant, structured guidance based on strict technical standards and real installation practices.

Verified answers, not just links.
When searching online, you usually face two extremes search engines that dump thousands of links you have to verify yourself, or generic AI models that hallucinate and lack technical context. We built something different.
AdvisorAI combines:
Structured technical knowledge
National building standards
Exact product parameters
Real installation scenarios
You get precise, context-aware guidance you can actually trust on-site.
Question Engine
Describe the problem.
Get a technical answer.
The Question Engine allows installers to ask technical questions in natural language. Instead of searching through documentation or forums, the installer can simply describe the installation challenge.
AdvisorAI analyses the question and provides structured guidance based on technical knowledge, standards and practical installation scenarios.
Typical use cases include:
- choosing the right technology for a project
- understanding installation requirements
- interpreting technical parameters
- finding compatible components
- identifying possible alternatives
This tool is the fastest way to move from a technical problem to a clear solution.
Why this is different from traditional search or general AI tools
When searching online, installers often face two extremes:
- Search engines provide lists of links that still need to be opened, analysed and verified.
- General AI models may generate answers, but without verified technical context it is often difficult to trust the result.
- Assemblico works differently.
The platform combines structured technical knowledge, standards, product parameters and installation tools in one environment.
This means the installer receives precise, context-aware and technically verified guidance, not just links or generic AI responses.

USE CASES
See Question Engine in action
For Installers & Technical Professionals
Does a warehouse lighting installation with an 8 m mounting height meet EN 12464 requirements if I use 150W LED high-bay fixtures?
AdvisorAI answer:
EN 12464-1 requires a minimum illumination level of 300 lux for typical warehouse operations.
Based on the installation height of 8 m and assuming fixtures with an efficacy of 150 lm/W and a beam angle suitable for high-bay applications, the lighting layout must ensure uniform distribution across the workspace.
To confirm compliance, the installation should also meet:
- uniformity ratio ≥ 0.4
- glare control (UGR requirements depending on the task area)
A lighting calculation is recommended to verify spacing and fixture quantity.
What cable cross-section should be used for a 32A load over a 40 m cable run in a three-phase installation?
AdvisorAI answer:
For a 32A three-phase load over a 40 m distance, the cable cross-section must be selected considering:
• current carrying capacity
• voltage drop limits
• installation method
According to IEC 60364 voltage drop recommendations, the total drop should not exceed 3% for lighting circuits and 5% for other loads.
In most typical installation conditions, a 5×6 mm² copper cable is commonly suitable, but the final selection depends on:
• installation method (conduit, tray, buried)
• ambient temperature
• grouping of cables
Can metal-halide fixtures be replaced with LED fixtures without changing the wiring?
AdvisorAI answer:
In many retrofit projects LED fixtures can replace metal-halide luminaires, but several parameters must be verified:
• operating voltage compatibility
• removal of magnetic or electronic ballasts
• inrush current of LED drivers
• circuit protection ratings
In most cases the ballast must be bypassed and the LED driver connected directly to mains supply.
What illumination level is required for office workplaces according to European standards?
AdvisorAI answer:
According to EN 12464-1, the recommended maintained illuminance for office workplaces is:
• 500 lux on the task area
• 300 lux in surrounding areas
Additional requirements include:
• UGR ≤ 19
• colour rendering index Ra ≥ 80
How many fire detectors are required for a 600 m² office floor?
AdvisorAI answers:
According to EN 54 and typical fire detection design rules, the coverage of smoke detectors depends on ceiling height and room layout.
For standard ceilings up to 6 m, one detector typically covers 60–80 m².
For a 600 m² open office area, the system would typically require 8–10 detectors, depending on layout and obstructions.